Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacitance | 52 ± 2 pF/m |
Velocity of propagation | %85 ± 2 |
Insulation resistance min | 2 G Ω x km |
Operating voltage max. | 2000 V |
Test voltage | 5000 V |
Standarts | EN 50117, IEC 61196 |
Fire performance | Düşey alev yayılma EN 60332-1-2 |
Satellite distribution | 2150MHz – 90m |
VHF/UHF distribution | 860MHz – 230m |
S-band Cable TV distribution | 470MHz – 310m |
Attenuation @20°C max | 50 MHz 3,15 dB/100m 200 MHz 6,18 dB/100m 470 MHz 9,60 dB/100m 860 MHz 13,29 dB/100m 1000 MHz 14,43 dB/100m 2150 MHz 22,25 dB/100m 2400 MHz 23,73 dB/100m 3000 MHz 27,06 dB/100m |
Return loss | 5-470 MHz > 23 dB 470-1000MHz > 20 dB 1000-2000 MHz > 18 dB 2000-3000 MHz > 16 dB |
Screen Attenuation
Screening Class |
30-1000 MHz ≥ 95 dB Class A+ |
Transfer Impedance | 5-30 MHz ≤ 2,5 mΩ/m |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems.
Conductor Electrolytic copper wire, Ø 1.63 mm (AWG14)
Insulation Physical foam PE, Ø 7.11 mm 70°C, EN 50290-2-23
Screen Cu-Pet foil min. 100% coverage Electrolytic braided copper wire Cu-Pet foil min. 100% coverage
Sheath PVC – RAL 6018 Black/Green, Ø 10.0 mm TM51 70°C, EN 50290-2-22