RG 11 U/4 PHY-PVC (Cu/Al)

Categories: ,

Operating temperature -30 °C … +70 °C
Bending radius min. 10 x D
Impedance 75 ± 3 Ω
Capacitance 52 ± 2 pF/m
Velocity of propagation %84 ± 2
Insulation resistance min 2 G Ω x km
Operating voltage max. 2000 V
Test voltage 5000 V
Standartlar EN 50117, IEC 61196
Fire performans Düşey alev yayılma EN 60332-1-2
Satellite distribution2) 2150MHz – 90m
VHF/UHF distribution3) 860MHz – 230m
S-band Cable TV distribution3) 470MHz – 310m
Attenuation @20°C max 50 MHz 3,15 dB/100m
200 MHz 6,18 dB/100m
470 MHz 9,60 dB/100m
860 MHz 13,29 dB/100m
1000 MHz 14,43 dB/100m
2150 MHz 22,25 dB/100m
2400 MHz 23,73 dB/100m
3000 MHz 27,06 dB/100m
Return Loss 5-470 MHz > 23 dB
470-1000MHz > 20 dB
1000-2000 MHz > 18 dB
2000-3000 MHz > 16 dB
Screen Attenuation 30-1000 MHz ≥ 75 dB
1000-2000MHz ≥ 65 dB
2000-3000 MHz ≥ 55 dB
Transfer Impedance 5-30 MHz ≤ 15 mΩ/m

Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems.

Conductor Electrolytic copper wire, Ø 1.63 mm (AWG14)

Insulation Physical foam PE, Ø 7.11 mm 70°C, EN 50290-2-23

Screen Al-Pet foil min. 100% coverage Aluminium braided wire

Sheath PVC – RAL 9011 Black/Orange, Ø 10.0 mm TM51 70°C, EN 50290-2-22