Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacitance | 54 ± 2 pF/m |
Velocity of propagation | %83 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 1000 V |
Test voltage | 2500 V |
Standards | EN 50117, IEC 61196 |
Fire performans | Vertical flame propagation EN 60332-1-2 |
Satellite distribution2) | 2150MHz – 40m |
VHF/UHF distribution3) | 860MHz – 100m |
S-band Cable TV distributio | 470MHz – 140m |
Attenuation @20°C max | 50 MHz 7,26 dB/100m 200 MHz 14,23 dB/100m 470 MHz 21,91 dB/100m 860 MHz 29,96 dB/100m 1000 MHz 32,43 dB/100m 2150 MHz 48,82 dB/100m 2400 MHz 51,83 dB/100m 3000 MHz 58,59 dB/100m |
Return Loss | 5-470 MHz > 20dB 470-1000MHz > 18 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems. Thanks to the small-diameter design, the cables are suitable for flush-mount electrical installation in walls and ceilings of the renovated buildings
Conductor Electrolytic copper wire, Ø 0.64 mm (AWG22)
Insulation Physical foam PE, Ø 2.90 mm 70°C, EN 50290-2-23
Screen Al-Pet foil min. 100% coverage Aluminium braided wire
Sheath PVC – RAL 9003 White, Ø 4.30 mm TM51 70°C, EN 50290-2-22