Operating temperature | -30 °C … +70 °C |
Bending radius | 10 x D |
Impedance | 75 ± 1 Ω |
Capacitance | 52 ± 2 pF/m |
Velocity of propagation | %85 ± 1 |
Insulation resistance | 2 G Ω x km |
Operating voltage max. | 2000 V |
Test voltage | 5000 V |
Standards | EN 50117, IEC 61196 |
Fire performance
EU declaration of conformity
|
Vertical flame propagation EN 60332-1-2
Corrosive gas EN 60754-1/2 Smoke density EN 61034-2 LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Satellite distribution2) | 2150MHz – 67m |
VHF/UHF distribution3) | 860MHz – 167m |
S-band Cable TV distribution3) | 470MHz – 230m |
Attenuation @20°C | 1 MHz 0.69 dB/100 m
5 MHz 1.18 dB/100 m 10 MHz 1.55 dB/100 m 50 MHz 3.15 dB/100 m 100 MHz 4.38 dB/100 m 200 MHz 6.18 dB/100 m 500 MHz 9.92 dB/100 m 800 MHz 12.77 dB/100 m 1000 MHz 14.43 dB/100 m 1500 MHz 18.10 dB/100 m 2250 MHz 22.85 dB/100 m 3000 MHz 27.06 dB/100 m 3500 MHz 29.67 dB/100 m 4000 MHz 32.17 dB/100 m 4500 MHz 34.56 dB/100 m 5000 MHz 36.88 dB/100 m |
Return loss1) | 5-300 MHz > 26 dB
300-3000 MHz > 22 dB 3000-5000 MHz > 15 dB |
Screen Attenuation | 30-1000MHz ≥ 95 dB 1000-2000 MHz ≥ 85 dB 2000-3000 MHz ≥ 75 dB |
Transfer Impedance | 5-30MHz ≤ 2,5 mΩ/m |
Screening Class
Segregation class |
Class A+
“d” EN 50174-2 |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are used in live broadcasts and studio recordings as they transmit digital and HDTV-SDI video and convey rich media content such as HD and 3G without interruption.
Conductor Electrolytic copper wire, Ø 1.63 mm (AWG14)
Insulation Physical foam PE, Ø 7.11 mm 70°C, EN 50290-2-23
Screen Al-Pet-Al foil min. 100% coverage Tinned braided copper wire 95% coverage
Sheath HFFR – RAL4007 Purple, Ø 10.1 mm 70°C, EN 50290-2-27