Operating Temperature | -30°C …+70°C |
Bending radius | min. 10 x D |
Impedance
Capacitance Velocity of propagation |
75 ± 3 Ω
52 ± 2 pF/m (85 ± 2)% |
Attenuation @20°C | max. 50 MHz 4.32 dB/
100 m 200 MHz 8.44 dB/ 100 m 470 MHz 13.05 dB/ 100 m 860 MHz 17.96 dB/ 100 m 1000 MHz 19.48 dB/ 100 m 2150 MHz 29.74 dB/ 100 m 2400 MHz 31.65 dB/ 100 m 3000 MHz 35.98 dB/100 m |
Insulation resistance min. | min. 2 GΩ x km |
Test voltage | 3000 V |
Operating voltage | Max 1300 V |
Standards | EN 50117, IEC 61196 |
Fire performance | Vertical flame propagation EN 60332-1-2 |
EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Return loss1)
5-470 MHz > 23 dB
470-1000 MHz > 20 dB
1000-2000 MHz > 18 dB
2000-3000 MHz > 16 dB
Screening Class Class A Segregation class “d” EN 50174-2
Screen Attenuation 30-1000 MHz ≥ 85 dB 1000-2000 MHz ≥ 75 dB 2000-3000 MHz ≥ 65 dB Transfer Impedance 5-30 MHz ≤ 5.0 mΩ/m
Cable assembly length Satellite distribution2) 2150 MHz 70 m VHF/UHF distribution3) 860 MHz 170 m S-band Cable TV distribution3) 470 MHz 230 m
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems.
Conductor Electrolytic copper wire, Ø 1.13 mm
Insulation Physical foam PE, Ø 4.80 mm 70°C, EN 50290-2-23
Screen Cu-Pet foil min. 100% coverage Electrolytic braided copper wire
Sheath PVC – RAL 2003 orange, Ø 6.90 mm TM51 70°C, EN 50290-2-22