5002

Categories: ,

Teknik Özellikler

Operating Temperature -30 °C … +70 °C
Bending radius min. 10 x D
Impedance 75 ± 3 Ω
Capacitance 52 ± 2 pF/m
Velocity of propagation %86 ± 2
Insulation resistance min. 2 G Ω x km
Operatin voltage max. 1300 V
Test voltage 3000 V
Standards EN 50117, IEC 61196
Fire performans Vertical flame propagation EN 60332-1-2
Satellite distribution2) 2150MHz – 67m
VHF/UHF distribution3) 860MHz – 167m
S-band Cable TV distribution3) 470MHz – 230m
Attenuation @20°C max 50 MHz 4,30 dB/100m
200 MHz 8,40 dB/100m
470 MHz 13,0 dB/100m
860 MHz 18,0 dB/100m
1000 MHz 19,5 dB/100m
2150 MHz 29,7 dB/100m
2400 MHz 31,7 dB/100m
3000 MHz 36,0 dB/100m
Return Loss 5-470 MHz > 23 dB
470-1000MHz > 20 dB
1000-2000 MHz > 18 dB
2000-3000 MHz > 16 dB
Screen Attenuation 30-1000MHz ≥ 95 dB
1000-2000 MHz ≥ 85 dB
2000-3000 MHz ≥ 75 dB
Transfer ımpedance 5-30MHz ≤ 2,5 mΩ/m
Screening Class Class A+
It is designed for the distribution of satellite and terrestrial broadcasts operating in the CATV distribution networks in accordance with EN 50117 standards. Used as distribution cable for indoor applications.
Conductor

Annealed copper wire

Ø 1,13mm

Insulation Physical foam PE Ø 4,80mm
Screen Al-Pet-Sy folyo %100 coverage
tinned copper wire mesh %80 coverage
Al-Pet foil %100 coverage
Sheath white PVC Ø 6,90mm