Operating Temperature | -30°C …+70°C |
Bending radius | min. 10 x D |
Impedance
Capacitance Velocity of propagation |
75 ± 3 Ω
54 ± 2 pF/m (83 ± 2)% |
Attenuation @20°C | 50 MHz 7.26 dB/
100 m 200 MHz 14.23 dB/ 100 m 470 MHz 21.91 dB/ 100 m 860 MHz 29.96 dB/ 100 m 1000 MHz 32.43 dB/ 100 m 2150 MHz 48.82 dB/ 100 m 2400 MHz 51.83 dB/ 100 m 3000 MHz 58.59 dB/100 m |
Insulation resistance min. | 2 GΩ x km |
Test voltage | 2500 V |
Operating voltage max. | 1000 V |
Standards | EN 50117, IEC 61196 |
Fire performance | Vertical flame propagation EN 60332-1-2 |
EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Cable assembly length Satellite distribution2) 2150 MHz 40 m VHF/UHF distribution3) 860 MHz 100 m S-band Cable TV distribution3) 470 MHz 140 m
Return loss1) 5-470 MHz > 20 dB 470-1000 MHz > 18 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB Segregation class “c” EN 50174-2
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems. Thanks to the small-diameter design, the cables are suitable for flush-mount electrical installation in walls and ceilings of the renovated buildings.
Conductor Electrolytic copper wire, Ø 0.64 mm (AWG22)
Insulation Physical foam PE, Ø 2.90 mm 70°C, EN 50290-2-23
Screen Cu-Pet foil min. 100% coverage Electrolytic braided copper wire
Sheath PVC – RAL 6018 Green, Ø 4.30×8.80 mm TM51 70°C, EN 50290-2-22