Operating temperature | -30 °C … +70 °C |
Bending radius | min 10 x D |
Impedance | 75 ± 1 Ω |
Capacitance | 54 ± 1 pF/m |
Velocity of propagation | %83 ± 1 |
Insulation resistance | 2 G Ω x km |
Operating voltage max | 1000 V |
Test voltage | 2500 V |
Standarts
EU declaration of conformity |
EN 50117, IEC 61196
LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Fire performance | Düşey alev yayılma EN 60332-1-2 Korozif gaz EN 50267-2-1/2 Duman yoğunluğu EN 61034-2 |
Data rate | SD- 270 Mb/s HD-1,5 Gb/s 3G-3,0 Gb/s |
Std. | SD- SMPTE 292M HD-SMPTE 259M 3G-SMPTE 424M |
Application | SD- Component SDI HD-720p-1080i 3G-1080p |
Assembly length | SD- 240 metre HD-80 metre 3G-45 metre |
Attenuation @20°C | 1 MHz 1,44 dB/100m 5 MHz 2,61 dB/100m 10 MHz 3,49 dB/100m 50 MHz 7,26 dB/100m 100 MHz 10,12 dB/100m 200 MHz 14,23 dB/100m 500 MHz 22,62 dB/100m 800 MHz 28,85 dB/100m 1000 MHz 32,43 dB/100m 1500 MHz 40,21dB/100m 2250 MHz 50,04 dB/100m 3000 MHz 58,59 dB/100m 3500 MHz 63,81 dB/100m 4000 MHz 68,75 dB/100m 4500 MHz 73,46 dB/100m 5000 MHz 77,97 dB/100m |
Return loss1) | 5-300 MHz > 26 dB 300-3000MHz > 22 dB 3000-5000 MHz > 15 dB |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are used in live broadcasts and studio recordings as they transmit digital and HDTV-SDI video and convey rich media content such as HD and 3G without interruption.
Conductor Electrolytic copper wire, Ø 0.64 mm (AWG22)
Insulation Physical foam PE, Ø 2.90 mm 70°C, EN 50290-2-23
Screen Al-Pet-Al foil min. 100% coverage
Tinned braided copper wire 95% coverage
Sheath HFFR – RAL4007 Purple, Ø 4.50 mm 70°C, EN 50290-2-27