HDV 160 HFFR

Categories: ,
Operating temperature -30 °C … +70 °C
Bending radius 10 x D
Impedance 75 ± 1 Ω
Capacitance 52 ± 2 pF/m
Velocity of propagation %85 ± 1
Insulation resistance 2 G Ω x km
Operating voltage max. 2000 V
Test voltage 5000 V
Standards EN 50117, IEC 61196
Fire performance

 

EU declaration of conformity

 

Vertical flame propagation EN 60332-1-2

Corrosive gas EN 60754-1/2 Smoke density EN 61034-2

LVD Low Voltage Directive 2014/35/EU

RoHS Restriction of Hazardous Substances 2011/65/EU

Satellite distribution2) 2150MHz – 67m
VHF/UHF distribution3) 860MHz – 167m
S-band Cable TV distribution3) 470MHz – 230m
Attenuation @20°C 1 MHz 0.69 dB/100 m

5 MHz 1.18 dB/100 m

10 MHz 1.55 dB/100 m

50 MHz 3.15 dB/100 m

100 MHz 4.38 dB/100 m

200 MHz 6.18 dB/100 m

500 MHz 9.92 dB/100 m

800 MHz 12.77 dB/100 m

1000 MHz 14.43 dB/100 m

1500 MHz 18.10 dB/100 m

2250 MHz 22.85 dB/100 m

3000 MHz 27.06 dB/100 m

3500 MHz 29.67 dB/100 m

4000 MHz 32.17 dB/100 m

4500 MHz 34.56 dB/100 m

5000 MHz 36.88 dB/100 m

Return loss1) 5-300 MHz > 26 dB

300-3000 MHz > 22 dB

3000-5000 MHz > 15 dB

Screen Attenuation 30-1000MHz ≥ 95 dB
1000-2000 MHz ≥ 85 dB
2000-3000 MHz ≥ 75 dB
Transfer Impedance 5-30MHz ≤ 2,5 mΩ/m
Screening Class

Segregation class

Class A+

“d” EN 50174-2

Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are used in live broadcasts and studio recordings as they transmit digital and HDTV-SDI video and convey rich media content such as HD and 3G without interruption.

Conductor Electrolytic copper wire, Ø 1.63 mm (AWG14)

Insulation Physical foam PE, Ø 7.11 mm 70°C, EN 50290-2-23

Screen Al-Pet-Al foil min. 100% coverage Tinned braided copper wire 95% coverage

Sheath HFFR – RAL4007 Purple, Ø 10.1 mm 70°C, EN 50290-2-27