Operating temperature | -30 °C … +70 °C |
Bending radius | 10 x D |
Impedance | 75 ± 3 Ω |
Capacitance | 52 ± 2 pF/m |
Velocity of propagation | %85 ± 2 |
Insulation resistance | 2 G Ω x km |
Operating voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | |
Fire performance | |
Satellite distribution2) | 2150MHz – 67m |
VHF/UHF distribution3) | 860MHz – 167m |
S-band Cable TV distribution3) | 470MHz – 230m |
Attenuation @20°C | 50 MHz 4,32 dB/100m 200 MHz 8,44 dB/100m 470 MHz 13,02 dB/100m 860 MHz 17,96 dB/100m 1000 MHz 18,48 dB/100m 2150 MHz 29,74 dB/100m 2400 MHz 31,65 dB/100m 3000 MHz 35,98 dB/100m |
Return loss1) | 5-470 MHz > 23 dB 470-1000MHz > 20 dB 1000-2000 MHz > 18 dB 2000-3000 MHz > 16 dB |
Screen Attenuation | 30-1000MHz ≥ 95 dB 1000-2000 MHz ≥ 75 dB 2000-3000 MHz ≥ 65 dB |
Transfer Impedance | 5-30MHz ≤ 5,0 mΩ/m |
Screening Class
Segregation class
|
Class A+
“d” EN 50174-2 |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems.
Conductor Electrolytic copper wire, Ø 1.13 mm Insulation Physical foam PE, Ø 4.80 mm 70°C, EN 50290-2-23 Screen Al-Pet-Sy foil min. 100% coverage Aluminium braided wire Al-Pet foil min. 100% coverage Sheath PVC – RAL 6018 Green, Ø 6.90 mm TM51 70°C, EN 50290-2-22