Operating Temperature | -30°C …+70°C |
Bending radius min. | min. 15 x D |
Impedance
Capacitance Velocity of propagation |
75 ± 3 Ω
54 ± 2 pF/m (83 ± 2)% |
Conductor resistance | max. 0.22 mm² 96 Ω/km
0.50 mm² 39 Ω/km |
Insulation resistance | min. 2 GΩ x km |
Test voltage | 2500 V |
Operating voltage max. | max 1000 V |
Standards | TSE K 212 |
Fire performance | Vertical flame propagation EN 60332-1-2 |
EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Attenuation @20°C
max. 1 MHz 2.2 dB/
100 m 5 MHz 4.0 dB/
100 m 10 MHz 5.4 dB/
100 m 20 MHz 7.3 dB/
100 m 30 MHz 8.8 dB/
100 m 50 MHz 11.2 dB/
100 m 100 MHz 15.6 dB/100 m
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and are used in indoor and dry environment CCTV closed circuit camera applications. Provides simultaneous transmission of video, power, audio and control signals
Conductor Stranded copper wire, 7×0.20 mm, Class 5, IEC 60228
Insulation Physical foam PE, Ø 2.50 mm, 70°C, EN 50290-2-23
Screen Al-Pet foil min. 100% coverage, Aluminium braided wire Conductor Stranded copper wire, 0.50 mm2 , Class 5, IEC 60228
Insulation PVC, Black-Red, TI52 EN 50290-2-21
Conductor Stranded copper wire, 0.22 mm2 , Class 5, IEC 60228
Insulation PVC, Yellow-Blue, TI52 EN 50290-2-21
Screen Al-Pet foil min. 100% coverage
Sheath PVC – RAL 7001 Grey, TM51 70°C, EN 50290-2-22