Operating Temperature | -30°C …+70°C |
Bending radius min. | min. 15 x D |
Impedance
Capacitance Velocity of propagation |
75 ± 3 Ω
54 ± 2 pF/m (83 ± 2)% |
Conductor resistance | max. 0.22 mm² 96 Ω/km
0.50 mm² 39 Ω/km |
Insulation resistance min. | min. 2 GΩ x km |
Test voltage | 2500 V |
Operating voltage max. | 1000 V |
Standards | TSE K 212 |
Fire performance | Vertical flame propagation EN 60332-1-2 Corrosive gas EN 60754-1/2 Smoke density EN 61034-2 |
EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |
Attenuation @20°C
max. 1 MHz 2.2 dB/
100 m 5 MHz 4.0 dB/
100 m 10 MHz 5.4 dB/
100 m 20 MHz 7.3 dB/
100 m 30 MHz 8.8 dB/
100 m 50 MHz 11.2 dB/
100 m 100 MHz 15.6 dB/100 m
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and are used in indoor and dry environment CCTV closed circuit camera applications. Provides simultaneous transmission of video, power, audio and control signals. Cables are composed of halogen-free materials (flame retardant materials that do not emit toxic gas or black dense smoke that lowers visibility). They are primarily used in highly populated areas that should have fire resistance, such as housing estates, hotels, shopping malls and smart buildings.
Conductor Stranded copper wire, 7×0.20 mm, Class 5, IEC 60228
Insulation Physical foam PE, Ø 2.50 mm, 70°C, EN 50290-2-23
Screen Al-Pet foil min. 100% coverage, Aluminium braided wire
Inner Sheath HFFR 70°C, EN 50290-2-27
Conductor Stranded copper wire, 0.50 mm², Class 5, IEC 60228
Insulation HFFR, Black-Red, 70°C EN 50290-2-26 Conductor Stranded copper wire, 0.22 mm², Class 5, IEC 60228
Insulation HFFR, Yellow-Blue, 70°C EN 50290-2-26
Separator Polyester tape min. 100% coverage
Sheath HFFR – RAL 7001 Grey, 70°C EN 50290-2-27