SL400 F/U23

Categories: ,
Temperature range fixed -20°C …+60°C

flexing 0°C …+50°C

Bending radius min. fixed min. 4 x D

flexing min. 8 x D

Tensile strength

Crushing strength

Impact strength

max. 100 N

min. 1000 N/10 cm

min. 10 impacts

Conductor resistance

Resistance imbalance

max. 85 Ω/km

max %2

Insulation resistance min.

Capacitance

Capacity imbalance

Rated impedance

Velocity of propagation

Propagation delay

Signal delay

min. 5000 MΩ x m

nom. 50 pF/m

max. 1600 pF/km

100 ± 5 Ω @100 MHz

67-69%

max. 537 ns/100 m

max. 45 ns/100 m

Test voltage 1000 V
Operating voltage max.

TCL

Coupling attenuation

Transfer impedance

Segregation class

max 72 V

min. “Level 2”

“Type II”

Class 2

“c” EN 50174-2

Standards ISO/IEC 11801 2nd ed., IEC 61156-5 EN 50173-1, EN 50288-5-1 ANSI EIA/TIA 568-C.2
Fire performance Vertical flame propagation EN 60332-1-2 (LSZH-PVC) Corrosive gas EN 60754-1/2 (LSZH) Smoke density EN 61034-2 (LSZH)
EU declaration of conformity LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU

This data cable range is designed for analogue and digital signal transmission in audio, video and data applications in data communication systems supporting 250 MHz, 1.0 Gbit/s 1 Gigabit Ethernet. Cables meet the requirements of structural cabling standards including ANSI EIA/TIA 568, ISO/IEC 11801 and EN 50173 Class E. IEEE 802.3:10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+

Conductor Electrolytic copper wire, Ø 23AWG

Insulation HDPE, in compliance with TIA 568 insulation colour coding 80°C, EN 50290-2-23 Cross separator PE

Screen Pet tape min. 100% coverage Tinned copper drain wire, Ø 26AWG Al-Pet tape min. 100% coverage

Sheath LSZH/LS0H – RAL 1018 Yellow, Ø 7.2 mm 70°C, EN 50290-2-27 PVC – RAL 7001 Grey, Ø 7.2 mm TM51 70°C, EN 50290-2-22 PE – RAL 9011 Black, Ø 7.2 mm 80°C, EN 50290-2-24