PDV/PDV-K

Category:
Temperature range -30°C …+70°C
Bending radius min. min. 10 x D
Capacitance

Capacity imbalance max.

max. 56 nF/km

400 pF/500 m

Conductor resistance max. 97.8 Ω/km
Insulation resistance min. min. 5000 MΩ x km
Test voltage 1000 V
Operating voltage max. Max 250 V
Standards ISO/IEC 11801 2nd ed., IEC 61156-5 EN 50173-1, EN 50288-3-1 ANSI EIA/TIA 568-C.2
Fire performance Vertical flame propagation EN 60332-1-2 (LSZH-PVC)

Corrosive gas EN 60754-1/2 (LSZH) Smoke density EN 61034-2 (LSZH)

EU declaration of conformity LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU

The PE, Polyethylene insulated and PVC sheathed cable range is used as telephone cables in fixed interior installations in dry or wet areas. Used in telephone switchboards and subscriber distribution networks.

Conductor Electrolytic copper wire, Ø 0.50 mm (PDV) Tinned copper wire, Ø 0.50 mm (PDV-K)

Insulation HDPE, in compliance with IEC 60708 insulation colour coding 80°C, EN 50290-2-23

Strand Double stranding up to 10 pairs, 10 pairs 5 quad (bundle), Core is produced by bundling >10 pairs. Sheath PVC – RAL 7001 Grey TM51 EN 50290-2-22, YM1 DIN VDE 0207-5