Operating Temperature | -30 °C … +70 °C |
Bending radius | 10 x D |
Impedance | 75 ± 3 Ω |
Capacitance | 52 ± 2 pF/m |
Velocity of propagation | %84 ± 2 |
Insulation resistance | 2 G Ω x km |
Operating voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | EN 50117, IEC 61196 |
Fire performans | Vertical flame propagation EN 60332-1-2 |
Satellite distribution2) | 2150MHz – 60m |
VHF/UHF distribution3) | 860MHz – 150m |
S-band Cable TV distribution3) | 470MHz – 210m |
Attenuation @20°C max | 50 MHz 4,74 dB/100m 200 MHz 9,29 dB/100m 470 MHz 14,35 dB/100m 860 MHz 19,72 dB/100m 1000 MHz 21,37 dB/100m 2150 MHz 32,52 dB/100m 2400 MHz 34,59 dB/100m 3000 MHz 39,26 dB/100m |
Return Loss | 5-470 MHz > 20dB 470-1000MHz > 18 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB |
Utilising physical foam insulation technology, cables have a rated impedance of 75 ohms and comply with EN 50117. They are primarily used in Cable TV, individual/central satellite distribution and CCTV security camera systems.
Conductor Copper-clad steel wire, Ø 1.02 mm (AWG18) 21% conductive Insulation Physical foam PE, Ø 4.60 mm 70°C, EN 50290-2-23
Screen Cu-Pet foil min. 100% coverage
Electrolytic braided copper wire Cu-Pet foil min. 100% coverage
Sheath PVC – RAL 9003 White, Ø 6.80 mm TM51 70°C, EN 50290-2-22